189
XMEGA A [MANUAL]
8077I–AVR–11/2012
has effect on the RTC. This synchronization time is described for each register. Refer to
“RTCCTRL – RTC Control17.2.2 Interrupts and Events
The RTC can generate both interrupts and events. The RTC will give a compare interrupt and/or event at the first count
after the counter value equals the Compare register value. The RTC will give an overflow interrupt request and/or event
at the first count after the counter value equals the Period register value. The overflow will also reset the counter value to
zero.
Due to the asynchronous clock domain, events will be generated only for every third overflow or compare match if the
period register is zero. If the period register is one, events will be generated only for every second overflow or compare
match. When the period register is equal to or above two, events will trigger at every overflow or compare match, just as
the interrupt request.